Storage System Hardware Components
93
Enterprise Virtual Array 3000 User Guide
Using the Alphanumeric Display
The two-character alphanumeric display is located at the top of the EMU. See 1,
. This 7-segment display provides information about multiple enclosure
functions. The pushbuttons control the data displayed or entered.
Table 18: EMU LED Displays
EMU LED
Green
Power LED
Green
Fault LED
Amber
Status and Recommended Actions
Flashing
Flashing
Flashing
The EMU locate function is active. This
display has precedence over all others.
Fault conditions cannot be displayed
when the locate function is active.
Flashing
On
Off
The EMU is operational. The enclosure
power (both +5 V DC and +12 V DC)
is present and correct. There are NO
enclosure faults.
Flashing
On
On
The EMU is operational. There is an
enclosure fault. Check the
alphanumeric display error code for
detailed information about the
problem.
Flashing
Off
Off
The EMU is operational. This display
may be present when power is initially
applied to the enclosure.
Note:
When the +5 VDC is incorrect,
all the LEDs are Off.
On
On
Off
There is an EMU fault
There is no enclosure fault.
Off
On
Off
There is an EMU fault
There is no enclosure fault.
Off
Off
Off
There is an enclosure fault.
Either +5 VDC is incorrect, or both
+5 VDC and +12 VDC are incorrect.
Other error conditions may exist.