14 noncritical condition-emu enclosure address – HP 3000 Enterprise Virtual Array User Manual

Page 179

background image

EMU Generated Condition Reports

179

Enterprise Virtual Array 3000 User Guide

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Reset the EMU, then observe the EMU to ensure the error is corrected.

3. If resetting the EMU did not correct the problem, initialize the enclosure by:

a.

Removing power from the enclosure.

b.

Applying power to the enclosure.

4. Observe the EMU to ensure the error is corrected.

5. If initializing the enclosure did not correct the problem, contact your HP

authorized service representative.

0.7.01.14 NONCRITICAL Condition

EMU Enclosure Address

Either the enclosure address is incorrect or the enclosure has no address. Possible
causes include a defective enclosure address bus cable, an incorrectly connected
cable, or a defective enclosure address bus JB. This condition report remains
active until the problem is corrected.

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Remove and reconnect the cable between the address bus JB and the EMU.

Note:

The EMU display may not display a change in condition for up to 30 seconds.

3. Observe the EMU to ensure the error is corrected.

4. If the problem is not corrected, remove and reinstall the bottom and top

terminators, and all the JB-to-JB cables.

5. Observe the EMU to ensure the error is corrected.

6. Reset the EMU, then observe the EMU to ensure the error is corrected.

7. If resetting the EMU did not correct the problem, contact your HP authorized

service representative.