Power specifications – HP 3000 Enterprise Virtual Array User Manual
Page 159

Regulatory Notices and Specifications
159
Enterprise Virtual Array 3000 User Guide
Power Specifications
defines the AC power specifications for the storage system rack PDUs
and PDMs, drive enclosure power supplies, and controller enclosure power
supplies.
Table 41: Environmental Shipping or Short Term Storage Specifications
Ambient temperature: –40 °C to +66 °C (–40 °F to +151 °F)
Relative humidity: 10% to 80% (noncondensing)
Altitude: 15,240 m (50,000 ft)
Table 42: Enterprise Storage System AC Power Specifications
Nominal Input Voltage
Specifications
60-Hz Service
202 VAC
Voltage Range
Power Receptacle
Japan
180-220 VAC, 57-63Hz, 32 A, Single Phase
3-wire, 2-pole, IEC 309
208 VAC
Voltage Range
Power Receptacle
North America
180-220 VAC, 57-63Hz, 32 A, Single Phase
3-wire, 2-pole, NEMA L6-30
240 VAC
Voltage Range
Power Receptacle
Europe
208-254 VAC, 57-63 Hz, 32 A, Single Phase
3-wire, 2-pole, IEC 309
50-Hz Service
202 VAC
Voltage Range
Power Receptacle
Japan
180-220 VAC, 47-63Hz, 32 A, Single Phase
3-wire, 2-pole, IEC 309
220 VAC
Voltage Range
Power Receptacle
North America
190-235 VAC, 47-63Hz, 32 A, Single Phase
3-wire, 2-pole, NEMA L6-30
230 VAC
Voltage Range
Power Receptacle
North America
200-244 VAC, 47-63Hz, 32 A, Single Phase
3-wire, 2-pole, NEMA L6-30
240 VAC
Voltage Range
Power Receptacle
Europe
208-254 VAC, 57-63 Hz, 32 A, Single Phase
3-wire, 2-pole, IEC 309