beautypg.com

Power specifications – HP 3000 Enterprise Virtual Array User Manual

Page 159

background image

Regulatory Notices and Specifications

159

Enterprise Virtual Array 3000 User Guide

Power Specifications

Table 42

defines the AC power specifications for the storage system rack PDUs

and PDMs, drive enclosure power supplies, and controller enclosure power
supplies.

Table 41: Environmental Shipping or Short Term Storage Specifications

Ambient temperature: –40 °C to +66 °C (–40 °F to +151 °F)
Relative humidity: 10% to 80% (noncondensing)
Altitude: 15,240 m (50,000 ft)

Table 42: Enterprise Storage System AC Power Specifications

Nominal Input Voltage

Specifications

60-Hz Service

202 VAC

Voltage Range

Power Receptacle

Japan

180-220 VAC, 57-63Hz, 32 A, Single Phase

3-wire, 2-pole, IEC 309

208 VAC

Voltage Range

Power Receptacle

North America

180-220 VAC, 57-63Hz, 32 A, Single Phase

3-wire, 2-pole, NEMA L6-30

240 VAC

Voltage Range

Power Receptacle

Europe

208-254 VAC, 57-63 Hz, 32 A, Single Phase

3-wire, 2-pole, IEC 309

50-Hz Service

202 VAC

Voltage Range

Power Receptacle

Japan

180-220 VAC, 47-63Hz, 32 A, Single Phase

3-wire, 2-pole, IEC 309

220 VAC

Voltage Range

Power Receptacle

North America

190-235 VAC, 47-63Hz, 32 A, Single Phase

3-wire, 2-pole, NEMA L6-30

230 VAC

Voltage Range

Power Receptacle

North America

200-244 VAC, 47-63Hz, 32 A, Single Phase

3-wire, 2-pole, NEMA L6-30

240 VAC

Voltage Range

Power Receptacle

Europe

208-254 VAC, 57-63 Hz, 32 A, Single Phase

3-wire, 2-pole, IEC 309