beautypg.com

Power and cooling components, Enclosure power, 39 power supply and blower assembly components – HP 3000 Enterprise Virtual Array User Manual

Page 86

background image

Storage System Hardware Components

86

Enterprise Virtual Array 3000 User Guide

Caution:

Never remove more than one drive at a time, as this process can

cause the enclosure to overheat. To prevent overheating and ensure proper

operation, install a drive of equal or greater capacity, or a drive blank, as

soon as possible.

Power and Cooling Components

This section describes the function and general operation of the enclosure power
supplies and blowers.

Figure 39

identifies the major power supply assembly

components.

\

Enclosure Power

The two power supplies mount in the rear of the enclosure. The supplies are
auto-ranging and operate on a country-specific AC input voltage of
202 to 240 VAC ±10%, 50 to 60 Hz, ±5%, (188 to 264 VAC, 47 to 63 Hz).

The DC outputs of this power supply are:

+5.1 VDC for the EMU, I/O module, backplane, and drives

+12.1 VDC for the drives

+12.5 VDC for the blower

1

Power supply assembly

2

Power supply and blower status LED

3

AC Input connector with bail

4

Module latch (port-wine colored)

5

Blower tabs (port-wine colored)

6

Blower element

Figure 39: Power supply and blower assembly components

CXO7489A

1

3

4

5

5

6

2