HP 3000 Enterprise Virtual Array User Manual
Page 34

Storage System Description
34
Enterprise Virtual Array 3000 User Guide
Path A - Failover
Only
At initial presentation
The units are brought online to
Controller A.
On dual boot or controller
resynch
If cache data for a LUN exists on a
particular controller, the unit will be
brought online there. Otherwise, the units
are brought online to Controller A.
On controller failover
All LUNs are brought online to the
surviving controller.
On controller failback
All LUNs remain on the surviving
controller. There is no failback except if a
host moves the LUN using SCSI commands.
Path B - Failover
Only
At initial presentation
The units are brought online to
Controller B.
On dual boot or controller
resynch
If cache data for a LUN exists on a
particular controller, the unit will be
brought online there. Otherwise, the units
are brought online to Controller B.
On controller failover
All LUNs are brought online to the
surviving controller.
On controller failback
All LUNs remain on the surviving
controller. There is no failback except if a
host moves the LUN using SCSI commands.
Path A -
Failover/Failback
At initial presentation
The units are brought online to
Controller A.
On dual boot or controller
resynch
If cache data for a LUN exists on a
particular controller, the unit will be
brought online there. Otherwise, the units
are brought online to Controller A.
On controller failover
All LUNs are brought online to the
surviving controller.
On controller failback
All LUNs remain on the surviving
controller. After controller restoration, the
units that are online to Controller B and set
to Path A are brought online to Controller
A. This is a one time occurrence. If the host
then moves the LUN using SCSI
commands, the LUN will remain where
moved.
Table 2: Failback Preference Settings (Continued)
Setting
Point in Time
Behavior