beautypg.com

HP 3000 Enterprise Virtual Array User Manual

Page 34

background image

Storage System Description

34

Enterprise Virtual Array 3000 User Guide

Path A - Failover

Only

At initial presentation

The units are brought online to

Controller A.

On dual boot or controller

resynch

If cache data for a LUN exists on a

particular controller, the unit will be

brought online there. Otherwise, the units

are brought online to Controller A.

On controller failover

All LUNs are brought online to the

surviving controller.

On controller failback

All LUNs remain on the surviving

controller. There is no failback except if a

host moves the LUN using SCSI commands.

Path B - Failover

Only

At initial presentation

The units are brought online to

Controller B.

On dual boot or controller

resynch

If cache data for a LUN exists on a

particular controller, the unit will be

brought online there. Otherwise, the units

are brought online to Controller B.

On controller failover

All LUNs are brought online to the

surviving controller.

On controller failback

All LUNs remain on the surviving

controller. There is no failback except if a

host moves the LUN using SCSI commands.

Path A -

Failover/Failback

At initial presentation

The units are brought online to

Controller A.

On dual boot or controller

resynch

If cache data for a LUN exists on a

particular controller, the unit will be

brought online there. Otherwise, the units

are brought online to Controller A.

On controller failover

All LUNs are brought online to the

surviving controller.

On controller failback

All LUNs remain on the surviving

controller. After controller restoration, the

units that are online to Controller B and set

to Path A are brought online to Controller

A. This is a one time occurrence. If the host

then moves the LUN using SCSI

commands, the LUN will remain where

moved.

Table 2: Failback Preference Settings (Continued)

Setting

Point in Time

Behavior