Error Condition Report Format

Each EMU detected condition generates a condition report containing three pieces
of information.

Element Type
The first two-digit hexadecimal display defines the element type reporting the
problem. The format for this display is e.t. with a period after each character.
0.1. through F.F. are valid element types.

Element Number
The second display is a two-digit decimal number that defines the specific
element reporting the problem. The format for this display is en. with a period
after the second character.

Error Code
The third display is a two-digit decimal number that defines the specific error
code. The format for this display is ec without any periods.

For detailed information about each condition report, including recommended
corrective actions, see “

EMU Generated Condition Reports” on page 161

.

Navigating the Error Condition Display

When an error condition occurs, the alphanumeric display changes to Er and the
error menu is active. The pushbuttons are used to display the error condition
values.

Perform the following procedure to display error conditions.

Figure 46

illustrates

the sequence for displaying error conditions.

1. With Er in the display, press and hold the top pushbutton until the first

element type is displayed. The most severe error in the queue will be
displayed.

2. Release the top pushbutton when the element type is displayed. The element

type has both decimal points lit.

3. Press and release the top pushbutton to display the element number. This

display has only the right decimal point lit.

4. Press and release the top pushbutton again to display the error code. This

display has no decimal points lit. Repeated press/release operations will cycle
through these three values.

5. Press and hold the top pushbutton from any of the three display states to move

to the element type for the next error condition in the queue.

6. Use the top pushbutton to display the values for the error condition.