Reset the iSCSI or iSCSI/FCoE module and boot the primary image

Use a pointed nonmetallic tool to briefly press the maintenance button for a duration of two seconds
and release it. The iSCSI or iSCSI/FCoE module responds as follows:

1.

The amber MEZZ status LED illuminates once.

NOTE:

Holding the maintenance button for more than two seconds but less than six seconds

or until the MEZZ status LED illuminates twice, boots a secondary image, and is not
recommended for field use.

2.

After approximately two seconds, the power-on self-test begins, and the MEZZ status LED is
turned off.

3.

When the power-on self test is complete, the MEZZ status LED illuminates and flashes once
per second.

Reset iSCSI or iSCSI/FCoE MGMT port IP address

Reset and restore the MGMT port IP address to the default of 192.168.0.76 or 192.168.0.82
depending on the controller 1 or 2 position.

NOTE:

Setting the IP address by this method is not persistent. To make the change persistent,

use the command line interface (CLI).

1.

Use a pointed nonmetallic tool to briefly press the maintenance button. Release the button
after six seconds and observe six extended flashes of the MEZZ status LED.

2.

The iSCSI or iSCSI/FCoE module boots and sets the MGMT port to IP address 192.168.0.76
or 192.168.0.82 depending on the controller 1 or 2 position.

Enable iSCSI or iSCSI/FCoE MGMT port DHCP address

Resets the iSCSI or iSCSI/FCoE module and configure the MGMT port to use DHCP to access its
IP address. Enabling DHCP by this method is not persistent. To make the change persistent, use
the CLI .

1.

Use a pointed nonmetallic tool to briefly press the maintenance button. Release the button
after seven seconds and observe seven extended flashes of the MEZZ status LED.

2.

The iSCSI or iSCSI/FCoE module boots and configures the MGMT port for DHCP.

Reset the iSCSI or iSCSI/FCoE module to factory defaults

This resets the iSCSI or iSCSI/FCoE module and restores it to the factory default configuration,
with reset passwords, MGMT port IP address set to either 192.168.0.76 or 192.168.0.82
depending on the controller 1 or 2 position, Disables iSCSI ports with no IP address, erases
presentations, and erases discovered initiators and targets).

1.

Use a pointed nonmetallic tool to press the maintenance button. Release the button after twenty
seconds and observe twenty extended flashes of the MEZZ status LED.

2.

The iSCSI or iSCSI/FCoE module boots and is restored to factory defaults.

HSV controller cabling

All data cables and power cables attach to the rear of the controller. Adjacent to each data
connector is a two-colored link status indicator.

Table 1 (page 25)

identifies the status conditions

presented by these indicators.

NOTE:

These indicators do not indicate whether there is communication on the link, only whether

the link can transmit and receive data.

The data connections are the interfaces to the disk drive enclosures, the other controller, and the
fabric. Fiber optic cables link the controllers to the fabric, and, if an expansion cabinet is part of
the configuration, link the expansion cabinet drive enclosures to the loops in the main cabinet.

HSV controller cabling

29