beautypg.com

Monitor multipath devices – HP EVA P6000 Storage User Manual

Page 122

background image

Target: iqn.2004-09.com.hp.fcgw.mez50.1.01.50014380025da538
Alias: -
Bi-directional Authentication: disabled
Authentication Type: NONE
Login Parameters (Default/Configured):
Data Sequence In Order: yes/-
Data PDU In Order: yes/-
Default Time To Retain: 20/-
Default Time To Wait: 2/-
Error Recovery Level: 0/-
First Burst Length: 65536/-
Immediate Data: yes/-
Initial Ready To Transfer (R2T): yes/-
Max Burst Length: 262144/-
Max Outstanding R2T: 1/-
Max Receive Data Segment Length: 8192/65536
Max Connections: 1/-
Header Digest: NONE/-
Data Digest: NONE/-
Configured Sessions: 1

Monitor Multipath devices

Once virtual disks are presented by HP P6000 Command View to the Solaris host, the following
commands should be used to monitor the configuration:
1.

iscsiadm list target -S

This command lists targets with their presented LUNs. In a multipath environment, the same
LUN number should appear under different EVA port targets from the same controller.

Example:

iscsiadm list target -S
Target: iqn.2004-09.com.hp.fcgw.mez50.2.01.50014380025da539
Alias: -
TPGT: 0
ISID: 4000002a0000
Connections: 1
LUN: 120
Vendor: HP
Product: HSV340
OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2

Target: iqn.2004-09.com.hp.fcgw.mez50.1.01.50014380025da538
Alias: -
TPGT: 0
ISID: 4000002a0000
Connections: 1
LUN: 120
Vendor: HP
Product: HSV340
OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2

2.

mpathadm list lu

This command lists the total and operational path count for each logical unit. Both controller
and device path counts are displayed.

Example:

#mpathadm list lu
/scsi_vhci/array-controller@g50014380025c4170
Total Path Count: 2
Operational Path Count: 2
/dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Total Path Count: 2

122

iSCSI or iSCSI/FCoE configuration rules and guidelines