beautypg.com

Ibm aix configuration, Requirements, Hba configuration – HP EVA P6000 Storage User Manual

Page 162: Risks, Limitations, Requirements hba configuration risks limitations

background image

IBM AIX configuration

Requirements

Switch zoning or controller level SSP must be used to ensure each single path HBA has an
exclusive path to its LUNs.

Single path HBA server can be in the same fabric as servers with multiple HBAs.

Single path HBA server cannot share LUNs with any other HBAs.

In the use of snapshots and snapclones, the source virtual disk and all associated snapshots
and snapclones must be presented to the single path hosts that are zoned with the same
controller. In the case of snapclones, after the cloning process has completed and the clone
becomes an ordinary virtual disk, you may present that virtual disk as you would any other
ordinary virtual disk.

HBA configuration

Host 1 is a single path HBA host.

Host 2 is a dual HBA host with multipathing software.

See

Figure 83 (page 163)

.

Risks

Single path failure may result in loss of data accessibility and loss of host data that has not
been written to storage.

Controller shutdown results in loss of data accessibility and loss of host data that has not been
written to storage.

NOTE:

For additional risks, see

“IBM AIX” (page 167)

.

Limitations

HP P6000 Continuous Access is not supported with single path configurations.

Single path HBA server is not part of a cluster.

Booting from the SAN is not supported.

162

Single path implementation