Configuring microsoft mpio iscsi devices – HP EVA P6000 Storage User Manual
Page 123

3.
mpathadm show lu ‘logical-unit’
This command lists details regarding a specific logical unit. This command can help verify
symmetric mode, load balancing, and autofailback settings, as well as path and target
port information.
Example:
#mpathadm show lu /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Logical Unit: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
mpath-support: libmpscsi_vhci.so
Vendor: HP
Product: HSV340
Revision: 0005
Name Type: unknown type
Name: 600508b4000b15a200005000038e0000
Asymmetric: no
Current Load Balance: none
Logical Unit Group ID: NA
Auto Failback: off
Auto Probing: NA
Paths:
Initiator Port Name: iqn.1986-03.com.sun:01:sansun-s04,4000002a00ff
Target Port Name: 4000002a0000,iqn.2004-09.com.hp.fcgw.mez50.2.01.
50014380025da539
Override Path: NA
Path State: OK
Disabled: no
Initiator Port Name: iqn.1986-03.com.sun:01:sansun-s04,4000002a00ff
Target Port Name: 4000002a0000,iqn.2004-09.com.hp.fcgw.mez50.1.01.
50014380025da538d
Override Path: NA
Path State: OK
Disabled: no
Target Ports:
Name: 4000002a0000,iqn.1986-03.com.hp:fcgw.MEZ50.0834e00028.
b2.01.50014380025c4179
Relative ID: 0
Name: 4000002a0000,iqn.2004-09.com.hp.fcgw.mez50.1.01.
50014380025da538
Relative ID: 0
Managing and Troubleshooting Solaris iSCSI Multipath devices
For further details on managing and troubleshooting a Solaris iSCSI multipath environment, see
Chapter 14 of the Solaris System Administration Guide: Devices and File Systems at
.
Configuring Microsoft MPIO iSCSI devices
For Microsoft MPIO, the load balance policies apply to each LUN individually. To display and
modify the LUN load balance policy (see
):
1.
Start the MS iSCSI control panel applet.
2.
Select the Target tab.
3.
Click Details.
4.
Click Devices.
5.
Highlight a LUN device name and click Advanced.
6.
Select the MPIO check box.
Set up the iSCSI Initiator
123