beautypg.com

HP EVA P6000 Storage User Manual

Page 286

background image

Table 35 iSCSI or iSCSI/FCoE module log messages (continued)

iSCSI login rejected due to a CHAP authentication
error.

Error

App

QLIS_LoginPduContinue:

Session does not exist,

invalid TSIH 0x%x

41353

iSCSI login rejected due to a CHAP key error.

Error

App

QLIS_LoginPduContinue:

Unexpected CHAP key detected

41354

Failed to allocate an object for Set Port Info IOCTL
processing: PortType: 0 = FC, 1 = iSCSIPortId: 0 =
FC1 or iSCSI1(GE1), 1 = FC2 or iSCSI2 (GE2)

Error

App

QLBI_SetPortInfo:

QLUT_AllocatePortalObject

failed (PortType 0x%x,

PortId 0x%x)

41508

Inquiry command failed. The Inquiry command was
issued by the module as part of its discovery
process.

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41626

Pass-Through command for Inquiry command for
page 83 failed. The Inquiry command was issued
by the module as part of its discovery process.

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41629

Pass-Through command for Read Capacity
command failed. The Read Capacity command was

Error

App

QLBI_Passthru: Invalid data

length %d bytes

41635

issued by the module as part of its discovery
process.

Read Capacity command failed. The Read Capacity
command was issued by the module as part of its
discovery process.

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41636

Pass-Through command issued by management
application (such as GUI) was aborted.

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41696

Pass-Through command issued by management
application (such as GUI) failed due to invalid
command descriptor block (CDB) length.

Error

App

QLBI_Passthru: Invalid CDB

length %d bytes

41700

Pass-Through command issued by management
application (such as GUI) failed due to invalid data
length.

Error

App

QLBI_Passthru: Invalid data

length %d bytes

41701

Pass-Through command issued by management
application (such as GUI) was interrupted or timed
out.

Error

App

QLBI_Passthru: Invalid data

length %d bytes

41717

IOCTL operation unsupported. Operation code
provided in log message.

Error

App

QLBI_Ioctl: ERROR: Operation

(0x%x) not supported in this

mode

41750

Report LUNs command failed. The Report LUNs
command was issued by the module as part of its
discovery process.

Error

App

QLBI_GetLunList: REPORT LUNS

command failed

41768

Report LUNs command failed with check condition
status. The Report LUNs command was issued by
the module as part of its discovery process.

Error

App

QLBI_GetLunList: REPORT LUNS

command failed with CHECK

CONDITION, SCSI STATUS

0x%02X

41769

Failed to allocate LUN object; out of resources.

Error

App

QLBI_GetLunList: Lun

allocation failed for LunId

%d

41771

Login attempted using FC virtual port (VP) index that
is out-of-range (range = 0–31). Index reported in
log message.

Error

App

QLFC_Login: VpIndex (%d) out

of range

41994

Login attempted using FC VP index that has not
been configured. Operation attempted on an
unconfigured VP.

Error

App

QLFC_Login: VP Index 0x%x

not configured

41995

286 iSCSI and iSCSI/FCoE module log messages