Failure effect

Fault stimulus

Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.

Server path failure

Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, replace cable, I/O continues. Without cable
replacement job must be aborted; disk seems error free.

Storage path failure

Windows Servers

Failure effect

Fault stimulus

OS runs a command called chkdsk when rebooting. Data lost, data that
finished copying survived.

Server failure (host power-cycled)

Write delay, server hangs until I/O is cancelled or cold reboot.

Switch failure (SAN switch disabled)

Write delay, server hangs or reboots. One controller failed, other
controller and shelves critical, shelves offline. Volume not accessible.
Server cold reboot, data lost. Check disk when rebooting.

Controller failure

Controller momentarily in failed state, server keeps copying. All data
copied, no interruption. Event error warning error detected during paging
operation.

Controller restart

Write delay, volume inaccessible. Host hangs and restarts.

Server path failure

Write delay, volume disappears, server still running. When cables
plugged back in, controller recovers, server finds volume, data loss.

Storage path failure

Oracle Solaris

Failure effect

Fault stimulus

Check disk when rebooting. Data loss, data that finished copying survived.

Server failure (host power-cycled)

Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages on console, no access to CDE.
System reboot causes loss of data on disk. Must newfs disk.

Switch failure (SAN switch disabled)

Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages on console, no access to CDE.
System reboot causes loss of data on disk. Must newfs disk.

Controller failure

Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages on console, no access to CDE.
System reboot causes loss of data on disk. Must newfs disk.

Controller restart

Short term: Data transfer stops. Possible I/O errors.
Long term: Repeated error messages on console, no access to CDE.
System reboot causes loss of data on disk. Must newfs disk.

Server path failure

Short term: Job hung, data lost.
Long term: Repeated error messages on console, no access to CDE.
System reboot causes loss of data on disk. Must newfs disk.

Storage path failure

OpenVMS

Failure effect

Fault stimulus

Nonclustered-Processes fail.
Clustered—Other nodes running processes that used
devices served from the single-path HBA failed over access

Server failure (host power-cycled)

Failure scenarios

165