An intermittent error has occurred, Table 2-6 when effects of a user, Lists whether the – HP XP7 Storage User Manual
Page 50
Table 2-6 When Effects of a User Changing the Intermittent Error
Information
User operation
Number of
errors and time
passed since
error
monitoring
started
Information
about paths
not subject to
automatic
failback
Changing the
intermittent error
monitoring settings
Turning off
Reset
Reset
#1
Changing the conditions for
an intermittent error while
intermittent error monitoring
is being performed
Reset
#2
Inherited
Turning intermittent error
monitoring on by executing
the set operation, (but not
changing the conditions)
while intermittent error
monitoring is being
performed
Clicking the Apply or OK
button in the HDLM GUI
Options window
#3
while
intermittent error monitoring
is being performed
Changing the intermittent
error monitoring conditions
while intermittent error
monitoring is not being
performed
(Not applicable)
(Not counted.)
Inherited
Changing the
automatic failback
settings
Turning off
Reset
Reset
Changing the path
status
Taking the path Offline(C) Reset
Reset
Placing the path Online
while intermittent error
monitoring is not being
performed
(Not applicable)
(Not counted.)
Reset
Placing the path Online
while intermittent error
monitoring is being
performed
Inherited
(Not applicable)
If a path has
been removed
from the paths
subject to
automatic
monitoring, that
path is no
longer
monitored.
Restarting the HDLM manager
Reset
#4
Inherited
2-30
HDLM Functions
Hitachi Dynamic Link Manager (for Windows®) User Guide