beautypg.com

An intermittent error has occurred, Table 2-6 when effects of a user, Lists whether the – HP XP7 Storage User Manual

Page 50

background image

Table 2-6 When Effects of a User Changing the Intermittent Error

Information

User operation

Number of

errors and time

passed since

error

monitoring

started

Information

about paths

not subject to

automatic

failback

Changing the

intermittent error

monitoring settings

Turning off

Reset

Reset

#1

Changing the conditions for

an intermittent error while

intermittent error monitoring

is being performed

Reset

#2

Inherited

Turning intermittent error

monitoring on by executing

the set operation, (but not

changing the conditions)

while intermittent error

monitoring is being

performed

Clicking the Apply or OK

button in the HDLM GUI
Options window

#3

while

intermittent error monitoring

is being performed

Changing the intermittent

error monitoring conditions

while intermittent error

monitoring is not being

performed

(Not applicable)

(Not counted.)

Inherited

Changing the

automatic failback

settings

Turning off

Reset

Reset

Changing the path

status

Taking the path Offline(C) Reset

Reset

Placing the path Online

while intermittent error

monitoring is not being

performed

(Not applicable)

(Not counted.)

Reset

Placing the path Online

while intermittent error

monitoring is being

performed

Inherited

(Not applicable)
If a path has

been removed

from the paths

subject to

automatic

monitoring, that

path is no

longer

monitored.

Restarting the HDLM manager

Reset

#4

Inherited

2-30

HDLM Functions

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: