beautypg.com

HP XP7 Storage User Manual

Page 131

background image

HDLM-installation-folder\bin\dlmprsvkey -v

Make sure that the PRSV key displayed by the dlmprsvkey utility is

unique among all the other hosts in the SAN. If the PRSV key is not

unique or not registered, or if the KAPL09131-W message appears,

execute the dlmprsvkey utility with the -r parameter specified to re-

register the PRSV key. If the PRSV key is unregistered, the HDLM

functions might not properly operate. For details about the dlmprsvkey

utility, see

The dlmprsvkey Utility for Registering an HDLM Persistent

Reservation Key on page 7-13

. If you used a license key file, it will be

deleted after the installation finishes. The KAPL09115-W message will

appear if deletion of this file fails. If this happens, delete the file

manually.

12

.

If you want to select an EMC CX series or an HP EVA series LU as the

HDLM management-target device, perform the following steps to register

it. Otherwise, go to step 17.

13

.

From Control Panel, choose MPIO.
The MPIO Properties dialog box opens.

14

.

On the MPIO-ed Devices page, click the Add button.
The Add MPIO Support dialog box opens.

15

.

Enter the Device hardware ID, and then click the OK button.

¢

For an EMC CX series:
Enter DGC RAID for the Device hardware ID.Enter five single-byte

spaces between DGC and RAID.

¢

For an HP EVA series:
Enter HP HSV for the Device hardware ID.Enter six single-byte

spaces between HP and HSV.

16

.

Click the OK button to close the MPIO Properties dialog box.

17

.

Shut down the host.
Leave the host in a single-path configuration until you check (in step 26)

whether HDLM has been successfully installed.

18

.

Perform steps 1 to 17 on all the hosts that make up the cluster system.

19

.

Make sure that all the hosts that make up the cluster system have

completely shut down.

20

.

Modify the storage system settings.
Modify the storage system settings by following the procedure described

in the maintenance documentation for that particular storage system.

21

.

Restart each host.

22

.

Log on to Windows again as a member of the Administrators group.

23

.

Execute the dlnkmgr command's view operation to display the status of

each program.
Make sure that on MSCS is displayed in Support Cluster. An example of

executing the dlnkmgr command's view operation is as follows:

PROMPT>dlnkmgr view -sys

Creating an HDLM Environment

3-63

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: