Setting up audit log data collection -80 – HP XP7 Storage User Manual
Page 148
KAPL01097-W message will be displayed to confirm the execution, and the
trace file will be temporarily deleted.
By specifying both the trace file size and the number of trace files, you can
collect up to 1024000KB of trace data.
•
Setting up the number of trace files by using the set operation
The following is an example of setting up the number of trace files by
using a command:
dlnkmgr set -systfn 10
Specify the number of trace files by using numbers.
Setting Up Audit Log Data Collection
If you want to collect audit log data, you must also specify the collection level
for audit log data and the audit log categories.
The table below lists and describes the values for the audit log collection level
setting. An audit log data collection level is a severity level. The default is 6.
Table 3-18 Values Indicating Audit Log Data Collection Levels
Value (severity)
Explanation
0
Error-level audit log data is collected.
1
2
3
4
Error-level and Warning-level audit log data is
collected.
5
6
Error-level, Warning-level, and Information-level
audit log data is collected.
7
The table below lists and describes the values for the audit log category
setting. The default is all.
Table 3-19 Values Indicating Audit Log Data Categories
Value
Explanation
ss
Audit log events of the StartStop category are collected.
c
Audit log events of the Authentication category are collected.
ca
Audit log events of the ConfigurationAccess category are collected.
all
Audit log events of the StartStop, Authentication, and
ConfigurationAccess categories are all collected.
This example shows how to enable the collection of audit log data:
3-80
Creating an HDLM Environment
Hitachi Dynamic Link Manager (for Windows®) User Guide