Kapl02001 to kapl03000, Kapl02001 to kapl03000 -30 – HP XP7 Storage User Manual
Page 328

Message ID
Message Text
Explanation
Specify a physical CHA port by
using the -cha -pathid
parameter, and then re-execute
the offline or online operation.
KAPL01174-W If the Physical Storage View is
disabled, the parameter value
aa...aa cannot be specified for
the -item parameter.
Details
If the Physical Storage View is
disabled, the parameter value
shown cannot be specified.
aa...aa: virt
Action
When specifying virtual storage
information as a display item,
enable the Physical Storage View.
KAPL01175-W If the Physical Storage View is
enabled, the parameter value
aa...aa cannot be specified for
the -item parameter.
Details
If the Physical Storage View is
enabled, the parameter value
shown cannot be specified.
aa...aa: phys, vid, ha, or hastat
Action
When specifying physical storage
information as a display item,
disable the Physical Storage View.
KAPL02001 to KAPL03000
Message ID
Message Text
Explanation
KAPL02001-I
HDLM GUI has started normally.
java.version = aa...aa
Details
aa...aa: Version
Action
None.
KAPL02002-I
HDLM GUI has terminated.
Action
None.
KAPL02003-E
You lack permission to start
HDLM GUI.
Action
Execute the command as a user
with Administrators group
permissions or as an
Administrator.
KAPL02004-E
An error occurred during
internal processing of HDLM
GUI. HDLM GUI cannot start.
Details = aa...aa
Details
During the GUI startup, an error
occurred that might not be a
result of a user operation.
aa...aa: Failed API name:
¢
JHSPGetPathBy
¢
JHSPGetManagerStatus
8-30
Messages
Hitachi Dynamic Link Manager (for Windows®) User Guide