beautypg.com

Examining the messages, Obtaining path information, Examining the messages -5 – HP XP7 Storage User Manual

Page 189: Obtaining path information -5

background image

Figure 5-2 Troubleshooting Procedure When a Path Error Occurs

The following shows the procedure for using the HDLM command (dlnkmgr)

to handle a path error.

Examining the Messages

Examine the messages that are output to the host event log. If the

KAPL08022-E message is output, view the message to check the path in

which the error has occurred. For details on each item displayed in messages,

see

Checking Error Information in Messages on page 5-2

.

If errors have occurred on all the paths to an LU, the KAPL08022-E message

will appear, in addition to the KAPL08026-E message.

When using the LU dynamic deletion function, the KAPL05301-E message will

appear if all the paths are deleted.

Obtaining Path Information

Obtain path information.

Execute the following command:

dlnkmgr view -path -iem -hbaportwwn > pathinfo.txt

pathinfo.txt is the redirection-output file name. Use a file name that

matches your environment.

Troubleshooting

5-5

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: