beautypg.com

HP XP7 Storage User Manual

Page 247

background image

Displayed Item

Description

No

summary

displayed

Summary

displayed

Own: Owner path

Non: Non-owner path
When connecting to the Lightning 9900V series, Hitachi

USP series, Universal Storage Platform V/VM series, Virtual

Storage Platform series, VSP G1000 series, Hitachi
AMS2000 series

#3

, Hitachi SMS series

#3

, HUS100

series

#3

, or HUS VM, all paths are owner paths.

For the EMC DMX series, EMC CX series, and HP EVA

series:
A hyphen (-) is displayed.

IO-
Count

#1

-

Total I/O count for the path, indicated by a decimal number.
The maximum value that can be displayed is 2

32

- 1

(4294967295). If the total I/O count reaches the maximum

value, it will re-start from 0.
To reset the IO-Count value to 0, execute the dlnkmgr

command's clear operation. Executing the clear operation

also resets the number of I/O errors (IO-Errors) to 0. For

details about the clear operation, see

clear (Returns the Path

Statistics to the Initial Value) on page 6-3

.

IO-
Errors

#1

-

Total I/O error count for the path, indicated by a decimal
number. The maximum value that can be displayed is 2

32

- 1

(4294967295). If the total I/O error count reaches the

maximum value, it will re-start from 0.
To reset the IO-Errors value to 0, execute the dlnkmgr

command's clear operation. Executing the clear operation

also clears the number of I/O operations (IO-Count) to 0.
For details about the clear operation, see

clear (Returns the

Path Statistics to the Initial Value) on page 6-3

.

DNum

#1

-

When Dev indicates an entire LU, 0 is displayed.

HDevName

#

1#4

-

Host device name.
A drive letter is displayed. If no drive letter has been assigned,

a hyphen (-) is displayed.
The drive letter is displayed in the HDevName field even if the

value of the DNum field is 0. Note, however, that the displayed

drive letter is the drive letter for one of the Devs included in

the LU.

IEP

#1

-

Information about the intermittent error.
This item is displayed only when you specify the -iem

parameter or when you specify iep for the -item parameter.
One of the following values is displayed for each path:

-
Indicates that intermittent error monitoring is disabled or

the monitoring time for an intermittent error is out of

Command Reference

6-55

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: