HP XP7 Storage User Manual
Page 253

Displays information only for the paths accessing the specified host
device, if the -hdev parameter is specified.
Specify a drive letter to indicate the desired host device. You cannot
specify the host device unless a drive letter has been assigned.If the
command ends with the KAPL01064-W or KAPL01013-E message,
follow the recommended action in the message.
If the -pathid parameter is specified, only information about the LU
connected to the path with the specified AutoPATH_ID is displayed.
-exlu
•
When an HDLM management-target device is the EMC DMX series,
EMC CX series, or HP EVA series:
If this parameter is specified, all 32 digits of the iLU are displayed
instead of truncating the iLU to 13 digits. If this parameter is not
specified, any characters after the 13
th
digit of the iLU of the EMC
DMX series, EMC CX series, and HP EVA series will not be
displayed. Ellipsis (...) will be displayed instead.
•
When an HDLM management-target device is only the Thunder
9500V series, Lightning 9900V series, Hitachi USP series, Hitachi
AMS2000/AMS/WMS/SMS series, HUS100 series, Universal
Storage Platform V/VM series, or Virtual Storage Platform series:
16 digits or less are displayed for the iLU even if this parameter is
specified.
-t
Omits the title for each information item.
Example
When the -exlu parameter is not specified:
PROMPT>dlnkmgr view -lu
Product : 9500V
SerialNumber : 0329
LUs : 2
iLU HDevName PathID Status
0000 P 000006 Online
000014 Online
0001 Q 000007 Online
000015 Online
Product : DGC
SerialNumber : -
LUs : 2
iLU HDevName PathID Status
6006016099C50... F 000004 Online
000008 Online
6006016099C50... G 000005 Online
000009 Online
Product : EMC
SerialNumber : -
LUs : 4
iLU HDevName PathID Status
6006048000018... L 000000 Online
Command Reference
6-61
Hitachi Dynamic Link Manager (for Windows®) User Guide