Message ID

Message Text

Explanation

Contact your HDLM vendor or the

maintenance company if there is a

maintenance contract for HDLM.

KAPL10080-I

Data for maintenance: aa...aa

bb...bb cc...cc dd...dd

Details

aa...aa: Maintenance information
bb...bb: Error number of the

Windows API (hexadecimal

number)
cc...cc and dd...dd: Fixed to 0

(hexadecimal number)

Action

None

KAPL10081-I

Data for maintenance: aa...aa

bb...bb cc...cc dd...dd

Details

aa...aa: Maintenance information
bb...bb: Error number of the

Windows API (hexadecimal

number)
cc...cc and dd...dd: Fixed to 0

(hexadecimal number)
ee...ee: The command that could

not be executed and the registry

key that could not be obtained.

Action

None

KAPL10640-I

The dlmpr utility completed

normally.

Details

The dlmpr utility for canceling the

HDLM persistent reserve finished

normally.

Action

None. For details on the dlmpr

utility, see

The dlmpr Utility for

Clearing HDLM Persistent

Reservations on page 7-10

.

KAPL10644-W The specified parameters cannot

be specified at the same time.

parameter = aa...aa

Details

aa...aa: Specified parameter

(character string)

Action

Execute the dlmpr utility for

clearing HDLM persistent

reservation with the -h parameter

to check the parameter, and then

retry. For details on the dlmpr

utility, see

The dlmpr Utility for

Clearing HDLM Persistent

Reservations on page 7-10

.

KAPL10646-W A parameter is invalid.

parameter = aa...aa

Details

Messages

8-91

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: