beautypg.com

HP XP7 Storage User Manual

Page 295

background image

Key name

#1

Description

#2

Necessity of

definition

Maximu

m

charact

er

length

#

3

New

installat

ion

Upgrade

installat

ion or

Re-

installat

ion

You can specify a value from 1 to
1440. The default is 30.

intermittent_err
or_monitor_numbe
r

#5

Specify how many times an error

needs to occur to cause HDLM to

assume an intermittent error.
You can specify a value from 1 to
99. The default is 3.

Optional

Optional

2

dynamic_io_path_
control

Specify whether to enable or

disable the dynamic I/O path

control function by using the

values below. Note that, if this

function is set, the setting for each

storage system or LU is cleared.
on: Enabled

off: Disabled (default)

Optional

Optional

3

dynamic_io_path_
control_interval

#6

For the dynamic I/O path control

function, specify the checking

interval (in minutes) for reviewing

the information about the

switching of controllers performed

by the storage system.
You can set the checking interval

from 1 to 1440. The default is 10.

Optional

Optional

4

remove_lu

Specify whether to enable the LU

dynamic removal function by

setting either of the following

values:
on: Enable the LU dynamic

removal function.
off: Disable the LU dynamic

removal function (default).

Optional

Optional

3

remove_lu_force

Using either of the following

values, specify whether to remove

an LU from the HDLM

management target list when all

paths to the LU are disconnected,

even when there are Offline(C)
paths:

#2

on: Remove the LU.

off: Do not remove the LU

(default).

Optional

Optional

3

Utility Reference

7-25

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: