Code

Explanation

Refresh the host information, check the path status, and then

perform the operation again.

1027

Details

The error monitoring interval and the number of times that the error

needs to occur are conflicting with the automatic failback-checking

interval.

Action

Set the intermittent error-monitoring interval to a value that is equal

to or greater than (automatic-failback-checking-interval x number-of-

times-error-is-to-occur-for-intermittent-error-monitoring).

1033

Details

An attempt to acquire the HDLM version information failed.

Action

Re-execute the command. If the same error occurs again, execute

the DLMgetras utility for collecting HDLM error information, and then

contact your HDLM vendor or maintenance company if there is a

maintenance contract for HDLM. For details on the DLMgetras utility,

see

The DLMgetras Utility for Collecting HDLM Error Information on

page 7-2

.

1034

Details

An attempt to acquire information about the HDLM version or SP

version has failed.

Action

Re-execute the command. If the same error occurs again, execute

the DLMgetras utility for collecting HDLM error information, and then

contact your HDLM vendor or maintenance company if there is a

maintenance contract for HDLM. For details on the DLMgetras utility,

see

The DLMgetras Utility for Collecting HDLM Error Information on

page 7-2

.

1035

Details

An attempt to acquire information about the HDLM version or SP

version has failed.

Action

Re-execute the command. If the same error occurs again, execute

the DLMgetras utility for collecting HDLM error information, and then

contact your HDLM vendor or maintenance company if there is a

maintenance contract for HDLM. For details on the DLMgetras utility,

see

The DLMgetras Utility for Collecting HDLM Error Information on

page 7-2

.

1036

Details

An attempt to acquire information about the HDLM version or SP

version has failed.

Action

Re-execute the command. If the same error occurs again, execute

the DLMgetras utility for collecting HDLM error information, and then

contact your HDLM vendor or maintenance company if there is a

maintenance contract for HDLM. For details on the DLMgetras utility,

Messages

8-115

Hitachi Dynamic Link Manager (for Windows®) User Guide

This manual is related to the following products: