HP XP7 Storage User Manual
Page 117
8
.
Specify a license key file or enter a license key by following the
instructions shown in the messages that appear in the window.
If a license key file was saved in step 5, specify that license key file.
If a license key file is not being used, specify the license key directly.
9
.
Specify the installation folder by following the instructions shown in the
messages that appear in the window.
The utility for registering HDLM persistent reservation keys (dlmprsvkey)
will be automatically executed. However, creation of the PRSV key might
be unsuccessful if, for example, an NIC does not exist. If the PRSV key is
created with time information only, or if key creation fails, a dialog box
will prompt you to enter the PRSV key.
If this dialog box appears, go to step 10; otherwise, go to step 12.
10
.
Enter the PRSV key by following the instructions shown in the dialog box.
The PRSV key is required for the HDLM functions to properly operate.
Also, the value of the PRSV key must be unique for each host.
11
.
If the KAPL09128-W message appears, you will need to re-enter the
correct PRSV key.
If a message does not appear, go to the next step.
12
.
The message Select Storage system to be managed. is displayed.
Click the Next button.
In an Oracle RAC environment, because an EMC DMX series or EMC CX
series LU cannot be set as an HDLM management-target device, do not
select EMC Symmetrix DMX Series, CLARiiON CX Series. Similarly,
because an HP EVA series LU cannot be set as an HDLM management-
target device, do not select HP StorageWorks EVA Series.
13
.
Follow the instructions shown in the messages that appear in the window.
¢
If a dialog box with the following text appears during installation, and
the Storport Miniport driver is being used as the HBA driver, stop the
HDLM installation. After that, install QFE838894 or a later version of
the Microsoft Storport driver, or install Windows Server 2003 SP1 or
later.
Notes on using a Storport Miniport driver
Read these notes before using a Storport Miniport driver as an
HBA driver.
The file version of the Storport.sys of this system
(Microsoft(R) Storport driver) is n.n.nnnn.n.
When using a Storport Miniport driver as an HBA driver:
Please update the Storport Miniport driver to a Storport.sys
with a file version n.n.nnnn.n or later.
¢
The PRSV key will be registered before the installation finishes. If the
KAPL09131-W message appears, follow the procedure described in
step 15.
¢
Although a message prompting you to restart the host appears after
the installation has finished, a restart is not necessary.
¢
In the last installation window, the following message might be
output:
Creating an HDLM Environment
3-49
Hitachi Dynamic Link Manager (for Windows®) User Guide