Revision b gsp, Configure system consoles – HP 9000 rp5400 Servers User Manual
Page 49

For the rev A GSP, the web console is accomplished by shipping one J3591A Secure Web Console
with each rp54xx server. The Secure Web Console can be used in place of an ASCII console to
provide console access via a web connection. If you are installing an rp54xx server that does not
have an ASCII console, you may use the Secure Web Console as the console. However, you must
first configure the Secure Web Console. Refer to
Secure Web Console Installation
for more
information on SWC Installation/Configuration.
Revision B GSP
The revision B GSP is identified by product number A6696B and part numbers: A6144-60012,
A6144-69012, and A6144-69112.
The revision B GSP requires an "M" cable to be attached to the DB25 connector. The part number
of the "M" cable is A6144-63001. The "M" cable provides female DB9 connectors for CONSOLE,
REMOTE, and UPS. The maximum supported baud rate for the CONSOLE and REMOTE
connectors is 38400 baud and 1200 baud for the UPS.
The paths for the CONSOLE, UPS, and REMOTE are 0/0/4/1.0, 0/0/4/1.1 and 0/0/4/1.2 respectively.
Configure System Consoles
rp54xx servers provide RS-232, REMOTE, LAN and WEB console access. All console access
involves the Guardian Service Processor (GSP). rp54xx servers use either a revision A or revision
B GSP. Below is an illustration of the console access provided by the revision A GSP.
The revision B GSP has embedded web access, eliminating the need for an external Secure Web
Console (SWC). Below is an illustration of the console access provided by the revision A GSP.
Configure System Consoles
49