Installing disk drives – HP 9000 rp5400 Servers User Manual
Page 43

•
On-line diagnostics provide information, verify and diagnose coverage for the graphics and
USB cards.Off-line diagnostics do not exist for either the graphics or USB card.
•
The HP-UX ioscan utility can be used to verify the HP-UX operating system recognized
the hardware.
Symptom: CDE will not come up.
1.
Ensure /dev/crt was created. If not created, use insf -e to create.
2.
Ensure the system is at run level 3. Use who -r to determine run level. Use init 3 to
change to run level 3.
3.
Ensure dt is enabled. Use /usr/dt/bin/dtconfig -eto enable dt.
4.
Ensure /etc/dt/config/Xservers exists. If not, use
/usr/dt/config/dtrc.d/20_graph_conf
to create.
5.
Ensure the line: * Local local@console /usr/bin/X11/X :0 is not commented out of the
/etc/dt/config/Xservers file.
6.
Reboot HP-UX.
Symptom: HP-UX does not recognize the graphics cards. unknown appears in the ioscan output
for these cards
.
1.
Examine the output of the swlist command to ensure the correct version of HP-UX is
installed.
2.
Update HP-UX as necessary
Installing Disk Drives
rp54xx servers support up to four optional internal hard drives. These drives must be installed
in the following sequence:
It is not necessary to shutdown the HP-UX operating system or power off the server to install a
new disk. Follow this procedure to add internal hard disk drives to your rp54xx server.
1.
If a front bezel is installed on the face of the server, open the right-hand panel to gain access
to the disk slots.
2.
Remove the disk drive slot cover.
3.
Insert the new disk drive into the slot until the rear connectors snap into place in the card
guide. As shown in the following graphic, the notches at the top of the disk drives must
snap over the small brackets in the disk bay to ensure a firm connection.
Installing Disk Drives
43