HP Hitachi Dynamic Link Manager Software User Manual
Page 49
User operation
Number of
errors and time
passed since
error
monitoring
started
Information
about paths
not subject to
automatic
failback
Changing the path
status
Taking the path Offline(C) Reset
Reset
Placing the path Online
while intermittent error
monitoring is not being
performed
(Not applicable)
(Not counted.)
Reset
Placing the path Online
while intermittent error
monitoring is being
performed
Inherited
(Not applicable)
If a path has
been removed
from the paths
subject to
automatic
monitoring, that
path is no
longer
monitored.
Restarting the HDLM manager
Reset
#4
Inherited
Restarting the host
Reset
Reset
#1
When you turn the intermittent error monitoring function off, information
about paths not subject to automatic failback will be reset. If you do not
want to reset the information about paths not subject to automatic
failback when you turn the intermittent error monitoring function off,
change the target paths to Offline(C).
#2
The number of errors and the time passed since error monitoring had
started are both reset to 0, and then monitoring restarts from the time
the setting change is made in accordance with the changed monitoring
conditions.
#3
When the settings for a function other than intermittent error monitoring
have been changed or even when the settings have not been changed, if
the Apply or OK button is clicked, the number of error occurrences and
the time since monitoring had started are both reset. To leave the
settings unchanged, close the Options window by clicking the Cancel
button. If you want to change the settings for a function other than
intermittent error monitoring but do not want to reset the intermittent
error monitoring status, use an HDLM command instead of the HDLM GUI.
#4
HDLM Functions
2-29
Hitachi Dynamic Link Manager User Guide (for Windows(R))