User operation

Number of

errors and time

passed since

error

monitoring

started

Information

about paths

not subject to

automatic

failback

Changing the path

status

Taking the path Offline(C) Reset

Reset

Placing the path Online

while intermittent error

monitoring is not being

performed

(Not applicable)

(Not counted.)

Reset

Placing the path Online

while intermittent error

monitoring is being

performed

Inherited

(Not applicable)
If a path has

been removed

from the paths

subject to

automatic

monitoring, that

path is no

longer

monitored.

Restarting the HDLM manager

Reset

#4

Inherited

Restarting the host

Reset

Reset

#1

When you turn the intermittent error monitoring function off, information

about paths not subject to automatic failback will be reset. If you do not

want to reset the information about paths not subject to automatic

failback when you turn the intermittent error monitoring function off,

change the target paths to Offline(C).

#2

The number of errors and the time passed since error monitoring had

started are both reset to 0, and then monitoring restarts from the time

the setting change is made in accordance with the changed monitoring

conditions.

#3

When the settings for a function other than intermittent error monitoring

have been changed or even when the settings have not been changed, if

the Apply or OK button is clicked, the number of error occurrences and

the time since monitoring had started are both reset. To leave the

settings unchanged, close the Options window by clicking the Cancel

button. If you want to change the settings for a function other than

intermittent error monitoring but do not want to reset the intermittent

error monitoring status, use an HDLM command instead of the HDLM GUI.

#4

HDLM Functions

2-29

Hitachi Dynamic Link Manager User Guide (for Windows(R))