When the following conditions are all satisfied, a path that has been

determined to have an intermittent error also becomes subject to

automatic failback:

¢

All the paths connected to an LU are Online(E), Offline(E), or
Offline(C).

¢

All the paths connected to an LU have been determined to have an

intermittent error.

¢

The processing of continuous I/O operations issued to an LU is

successful.

#5

During reserve processing for an LU, the Offline(E) status is temporarily

changed to Offline(P). After the reserve processing finishes, the
Offline(P) status is changed to Offline(C).

#6

When the following conditions are satisfied, the connected Offline(E)

paths are automatically placed online:

¢

All the online paths are Online(E) and all the SCSI devices connected

to the Online(E) paths have been deleted.

¢

The Offline(E) paths are assumed to have had an intermittent error,

and are thus excluded from automatic failbacks.

¢

The SCSI devices are connected to the Offline(E) paths.

If there is only one available online path for an LU, it cannot be placed offline

by using the Path Management window or by executing the offline

operation. This ensures that the LU can always be accessed by at least one

path. For details on the offline operation, see

offline (Places Paths Offline)

on page 6-6

.

If an error occurs in the only available online path for an LU, the status of the

path will change to Online(E).

If you are using the automatic failback function, after the path has recovered

from the error, HDLM will automatically place the path online. There are,

however, the following exceptions:

When you are using intermittent error monitoring, sometimes, the path in

which the intermittent error occurred is not automatically placed online

after the path has been recovered from the error. If this happens,

manually place the path online. If the only other online path is in the
Online(E) status when the path is recovered from the error, the path

recovered from the error might be placed online automatically. For

details, see

Figure 2-13 What Will Happen When an Intermittent Error

Does Not Occur on a Path on page 2-26

.

There are cases in which the path is automatically placed online even if

you are not using the automatic failback function. If a piece of hardware

that supports the Windows plug-and-play function is removed, HDLM will

place the path associated with that hardware offline, as well. If the

HDLM Functions