HP Hitachi Dynamic Link Manager Software User Manual
Page 379
Message ID
Message Text
Explanation
vendor or the maintenance
company if there is a maintenance
contract for HDLM.
If the WMI repository is corrupted,
consider rebuilding the repository.
KAPL12151-W A Windows Management
Instrumentation service access
error occurred. Details =
aa...aa, bb...bb
Details
A Windows Management
Instrumentation service access
error occurred.
The Windows Management
Instrumentation service might not
be working.
This message might also be
output when the WMI repository is
corrupted.
aa...aa: API name (character
string)
bb...bb: Error code (decimal
(base-10) number)
Action
Check whether the Windows
Management Instrumentation
service is working. If not, start it.
If the service cannot be started or
if the problem is not solved even
after restarting the service,
contact your HDLM vendor or the
maintenance company if there is a
maintenance contract for HDLM.
If the WMI repository is corrupted,
consider rebuilding the repository.
KAPL12152-W An error occurred during
internal processing of HDLM
Performance Monitor. Details =
aa...aa, bb...bb
Details
During Performance Monitor
processing, an error occurred that
was probably not a result of a
user operation.
There might not be enough
memory or the host might be
under a heavy load.
This message might also be
output when the WMI repository is
corrupted.
aa...aa: Internal processing name
(character string)
bb...bb: Error code (decimal
(base-10) number)
Action
Check the system status.
If this message is output
repeatedly, contact your HDLM
Messages
8-97
Hitachi Dynamic Link Manager User Guide (for Windows(R))