KAPL01001-I The HDLM command completed normally. Operation name =

view, completion time = yyyy/mm/dd hh:mm:ss

>

After you have set up the collection of audit log data, use the following

command to make sure that the setting has been specified correctly:

>dlnkmgr view -sys -audlog

Audit Log : on(6)

Audit Log Category : a11

KAPL01001-I The HDLM command completed normally. Operation name =

view, completion time = yyyy/mm/dd hh:mm:ss

>

Setting Up Integrated Traces

When HDLM is used, the dlnkmgr command and GUI operation logs are

output to the integrated trace information files of Hitachi Network Objectplaza

Trace Library (HNTRLib2) (installation-destination-drive:\Program
Files

#

\HITACHI\HNTRLib2\spool\Hntr2n.log files (n indicates a file

number)).

#

For Windows Server 2003 (excluding the x86 edition) or Windows Server

2008 (excluding the x86 edition), Program Files is Program Files
(x86).

If a lot of integrated trace information is output, the older information might

end up getting deleted in a very short amount of time. Also, if a large amount

of integrated trace information is suddenly all output at the same time, any

integrated trace information that is overflowing the buffer might not be saved

into the integrated trace files. To save as much information as possible,

change the settings for Hitachi Network Objectplaza Trace Library, increasing

the integrated trace file size and buffer size. Note that if the values are too

large, it will place a heavy load on the system. When determining these

values, be sure to consider these operational tradeoffs.

Table 3-20 Default and Recommended Values for the Integrated Trace File

Settings on page 3-79

shows the default and recommended values for the

integrated trace file settings.

Table 3-20 Default and Recommended Values for the Integrated Trace File

Settings

Setting

Default value

Recommended

value

Integrated trace file size

256 (KB)

4096 (KB)

Number of integrated trace files

4

8

Buffer size per

monitoring

interval

Monitoring cycle

10 (seconds)

5 (seconds)

Creating an HDLM Environment

3-79

Hitachi Dynamic Link Manager User Guide (for Windows(R))