Information Collected by the DLMgetras Utility for

Collecting HDLM Error Information

Immediately after an error occurs, execute the DLMgetras utility for collecting

HDLM error information, since restarting the machine might delete error

information before the information is collected by DLMgetras. For details

about the DLMgetras utility and the error information it collects, see

The

DLMgetras Utility for Collecting HDLM Error Information on page 7-2

.

Checking Error Information in Messages

You can check path errors by referring to the KAPL08xxx messages that are

output to the event log.

To obtain detailed information about a path failure, check the execution

results of the view operation as indicated by the error message.

For details on the view operation, see

view (Displays Information) on page

6-29

.

The following is an example of a message:

Message that is output when a path error occurs.

KAPL08022-E A path error occurred. ErrorCode = aa...aa, PathID =

bb...bb, PathName = cc...cc.dd...dd.ee...ee.ff...ff,DNum =

gg...gg,HDevName = hh...hh
KAPL08019-E The path (aa...aa) detected an error (bb...bb).

(cc...cc)

Message that is output when there is no online paths to an LU.

KAPL08026-E An error occurred on all the paths of the LU. PathID

= aa...aa

Message that is output when there is no online paths to an LU when the

LU dynamic removal function is used.

KAPL05301-E A path has been removed. Make sure that the path is

correctly connected to the LU, and then recover the path. If the

path cannot be recovered, execute the DLMgetras utility to

collect error information, and then contact your vendor or

maintenance company.

Refer to the HDLM User's Guide for instructions how to execute

the DLMgetras utility.

Notes:

¢

When a path not recognized by Windows is added to an LU for the

first time, the following messages might appear:
- KAPL08019-E and KAPL08022-E
- KAPL05301-E
Note that these messages are output by Windows activities, and not

by an error in HDLM.

¢

When an LU is deleted from the HDLM management target by using

the LU deletion function, the KAPL08022-E message might not be

5-2