beautypg.com

When mscs is used – HP Hitachi Dynamic Link Manager Software User Manual

Page 175

background image

Figure 4-1 Using the command to confirm that an LU has been added on

page 4-17

shows an example of using the command to confirm that an

LU has been added. For details about the HDLM GUI, see the HDLM GUI

Help.

Figure 4-1 Using the command to confirm that an LU has been

added

5

.

For the new LU, write a signature, create partitions, and then format it.

Note:

The PathID is determined by the system choosing the smallest,

available number that is not already in use for another path. For

example, when a path is deleted and then a new path is added, the

PathID for the added path might not be the same number as the

deleted PathID.

When MSCS is used

1

.

Add an LU.

2

.

Stop node B.

3

.

On node A, perform the steps shown in When MSCS is not used.

4

.

Stop node A, and then start node B.

5

.

On node B, perform the steps shown in When MSCS is not used.
When you create a partition, assign the same drive letter as the one

assigned for node A in step 3.

6

.

Stop node B, and then restart node A.

7

.

On node A, register the new LU in MSCS, and set it up.

8

.

Restart node B.

HDLM Operation

4-17

Hitachi Dynamic Link Manager User Guide (for Windows(R))

This manual is related to the following products: