HP Hitachi Dynamic Link Manager Software User Manual
Page 277

Key name
#1
Description
#2
Necessity of
definition
Maximu
m
charact
er
length
#
3
New
installat
ion
Upgrade
installat
ion or
Re-
installat
ion
path_health_chec
k_interval
Specify, in minutes, the interval at
which the path health check will be
performed.
You can specify a value from 1 to
1440. The default is 30.
Optional
Optional
4
auto_failback
Specify whether to enable
automatic failbacks for failed paths
by specifying either of the
following values:
on: Enable automatic failback
(default).
off: Disable automatic failback.
Optional
Optional
3
auto_failback_in
terval
Specify, in minutes, the path
status check interval, which is the
interval between the end of the
previous check and the start of the
next check.
You can specify a value from 1 to
1440. The default is 1.
Optional
Optional
4
intermittent_err
or_monitor
#4 #5
Specify whether to enable
intermittent error monitoring by
specifying either of the following
values:
on: Enable intermittent error
monitoring.
off: Disable intermittent error
monitoring (default).
Optional
Optional
3
intermittent_err
or_monitor_inter
val
#5
Specify, in minutes, the
intermittent error monitoring
interval.
You can specify a value from 1 to
1440. The default is 30.
Optional
Optional
4
intermittent_err
or_monitor_numbe
r
#5
Specify how many times an error
needs to occur to cause HDLM to
assume an intermittent error.
You can specify a value from 1 to
99. The default is 3.
Optional
Optional
2
remove_lu
Specify whether to enable the LU
dynamic removal function by
setting either of the following
values:
Optional
Optional
3
Utility Reference
7-23