Setting the number of trace files -77, Setting up audit log data collection -77 – HP Hitachi Dynamic Link Manager Software User Manual
Page 143
•
Setting up the trace file size by using the set operation
The following is an example of setting up the trace file size by using a
command:
>dlnkmgr set -systfs 2000
Specify the size of the trace file in kilobytes.
Setting the Number of Trace Files
Trace files for which the number of files can be set are hdlmtrn.log (n
indicates a file number from 1 to 64).
For the number of trace files, you can specify a value from 2 to 64. If you
specify a value smaller than the value that has already been specified, the
KAPL01097-W message will be displayed to confirm the execution, and the
trace file will be temporarily deleted.
By specifying both the trace file size and the number of trace files, you can
collect up to 1024000KB of trace data.
•
Setting up the number of trace files by using the set operation
The following is an example of setting up the number of trace files by
using a command:
>dlnkmgr set -systfn 10
Specify the number of trace files by using numbers.
Setting Up Audit Log Data Collection
If you want to collect audit log data, you must also specify the collection level
for audit log data and the audit log categories.
Table 3-18 Values Indicating Audit Log Data Collection Levels on page 3-77
describes the values that indicate audit log data collection levels. An audit log
data collection level is a severity level. The default is 6.
Table 3-18 Values Indicating Audit Log Data Collection Levels
Value (severity)
Explanation
0
Error-level audit log data is collected.
1
2
3
4
Error-level and Warning-level audit log data is
collected.
5
6
Error-level, Warning-level, and Information-level
audit log data is collected.
Creating an HDLM Environment
3-77
Hitachi Dynamic Link Manager User Guide (for Windows(R))