HP Hitachi Dynamic Link Manager Software User Manual
Page 119
If you have performed an unattended installation, check the installation
results from the command prompt.
9
.
After the installation finishes, execute the dlmprsvkey utility with the -v
parameter specified.
Execute the following command:
HDLM-installation-folder\bin\dlmprsvkey -v
Make sure that the PRSV key displayed by the dlmprsvkey utility is
unique among all the hosts in the SAN. If the PRSV key is not unique or
not registered, or if the KAPL09131-W message appears, execute the
dlmprsvkey utility with the -r parameter specified to re-register the PRSV
key. If the PRSV key is unregistered, HDLM functions might not properly
operate. For details about the dlmprsvkey utility, see
Utility for Registering an HDLM Persistent Reservation Key on page 7-12
.
If you used a license key file, it will be deleted after the installation
finishes. The KAPL09115-W message will appear if deletion of this file
fails. If this happens, delete the file manually.
10
.
If you want to select an EMC CX series LU as the HDLM management-
target device, perform the following steps to register it. Otherwise, go to
step 15.
11
.
From Control Panel, choose MPIO.
The MPIO Properties dialog box opens.
12
.
On the MPIO-ed Devices page, click the Add button.
The Add MPIO Support dialog box opens.
13
.
For Device Hardware ID, enter DGC RAID, and then click the OK button.
Enter five single-byte spaces between DGC and RAID.
14
.
Click the OK button to close the MPIO Properties dialog box.
15
.
Shut down the host.
Leave the host in a single-path configuration until you check (in step 23)
whether HDLM has been successfully installed.
16
.
Modify the storage system settings.
Modify the storage system settings by following the procedure described
in the maintenance documentation for that particular storage system.
17
.
Start the host.
18
.
Log on to Windows again as a member of the Administrators group.
19
.
Check the log file and PRSV key.
This step is unnecessary if you have performed step 9. In this case, go to
step 20.
If you installed HDLM by performing an unattended installation and
specified y for the restart key in the installation-information settings file,
make sure that the KAPL09181-I message is output to installhdlm.log.
For details about this log file, see
Notes on an Unattended Installation on
Preparations for Installing HDLM by Performing an
Unattended Installation on page 3-26
in
The installhdlm Utility for Installing HDLM on page 7-16
Creating an HDLM Environment
3-53
Hitachi Dynamic Link Manager User Guide (for Windows(R))