beautypg.com

Operation – KROHNE OPTIFLEX 2200 C_F EN User Manual

Page 96

background image

6

OPERATION

96

OPTIFLEX 2200 C/F

www.krohne.com

07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en

ERR 209 Sensor not

compatible

1

The software version of the

sensor is not compatible with the

software version of the signal

converter.

Go to menu 1.1.0 IDENT. in

Configuration mode. Record the

version numbers of the device

software given in menu items

1.1.2, 1.1.3 and 1.1.4. Give this

data to the supplier.

1

Defective wiring.

ERR 210 Empty

2, 4

The level is in the bottom dead

zone. There is a risk that the tank

is empty.

Add some of the product until

the level is above the bottom

dead zone.

INFORMATION!
In 4.0.0 MASTER menu, the type of error shown for error codes 102, 201 and 203 can be changed
from "Error" to "Warning" (the NE 107 status signal changes from "Failure" to "Out of
specification"). For more data, speak to the supplier.

Error

code

Error Message

Status marker

shown

Cause

Corrective action