beautypg.com

Technical data – KROHNE OPTIFLEX 2200 C_F EN User Manual

Page 133

background image

TECHNICAL DATA

8

133

OPTIFLEX 2200 C/F

www.krohne.com

07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en

Single probes: Dimensions in mm

Single probes: Dimensions in inches

Probes

Dimensions [mm]

L min.

L max.

m

t

Single rod Ø8 mm

1

1000

2

4000

-

-

Single rod Ø8 mm (segmented)

3

1000

2

6000

-

-

Single cable Ø2 mm

4

1000

2

40000

100

Ø14

Single cable Ø4 mm

5

1000

2

40000

100

Ø20

1 A device with this probe option must be assembled on site. For the assembly procedure, refer to "How to assemble the single rod probe

(single-piece probe)" in the Installation chapter.

2 A shorter probe length is available on request
3 A device with this probe option must be assembled on site. For the assembly procedure, refer to "How to assemble the single rod probe

(segmented probe)" in the Installation chapter.

4 1 counterweight option (Ш14Ч100 mm)
5 Refer to the end of this section for data about all the probe end options

Probes

Dimensions [inches]

L min.

L max.

m

t

Single rod Ø0.31¨

1

39

2

158

-

-

Single rod Ø0.31¨ (segmented)

3

39

2

236

-

-

Single cable Ø0.08¨

4

39

2

1575

3.9

0.6

Single cable Ø0.16¨

5

39

2

1575

4.0

0.8

1 A device with this probe option must be assembled on site. For the assembly procedure, refer to "How to assemble the single rod probe

(single-piece probe)" in the Installation chapter.

2 A shorter probe length is available on request
3 A device with this probe option must be assembled on site. For the assembly procedure, refer to "How to assemble the single rod probe

(segmented probe)" in the Installation chapter.

4 1 counterweight option (Ш0.6Ч3.9¨)
5 Refer to the end of this section for data about all the probe end options