Technical data – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 137
TECHNICAL DATA
8
137
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
Converter and probe housing weights
Probe weights
Type of housing
Weights
Aluminium housing
Stainless steel housing
[kg]
[lb]
[kg]
[lb]
Non-Ex / intrinsically-safe (Ex i / IS)
Non-Ex / intrinsically-safe (Ex i / IS)
Non-Ex / intrinsically-safe (Ex i / IS)
Non-Ex / intrinsically-safe (Ex i / IS)
Compact
2.8
6.2
6.4
14.1
Remote converter
1
2.5
5.5
5.9
13.0
Probe housing
1
1.8
4.0
3.9
8.6
Explosion proof (Ex d / XP)
Explosion proof (Ex d / XP)
Explosion proof (Ex d / XP)
Explosion proof (Ex d / XP)
Compact
3.2
7.1
7.5
16.5
Remote converter
1
2.9
6.40
7.1
15.65
Probe housing
1
1.8
4.0
3.9
8.6
1 The remote version of the device has a "remote converter" and a "probe housing". For more data, refer to "Housing dimensions" at the
start of this section.
Probes
Min. process connection size
Weights
Thread
Flange
[kg/m]
[lb/ft]
Single cable Ø2 mm / 0.08¨
G ½A; ½ NPTF
DN25 PN40; 1¨ 150 lb; 1½¨ 300 lb
0.016
1
0.035
1
Single cable Ø4 mm / 0.16¨
G ¾A; ¾ NPT
DN25 PN40; 1¨ 150 lb; 1½¨ 300 lb
0.12
1
0.08
1
Double cable Ø4 mm / 0.16¨
G 1½A; 1½ NPT
DN50 PN40; 2¨ 150 lb; 2¨ 300 lb
0.24
1
0.16
1
Single rod Ø8 mm / 0.31¨
G ¾A; ¾ NPT
DN25 PN40; 1¨ 150 lb; 1½¨ 300 lb
0.41
2
0.28
2
Double rod Ø8 mm / 0.31¨
G 1½A; 1½ NPT
DN50 PN40; 2¨ 150 lb; 2¨ 300 lb
0.82
2
0.56
2
Coaxial Ø22 mm / 0.9¨
G ¾A; ¾ NPT
DN25 PN40; 1¨ 150 lb; 1½¨ 300 lb
0.79
2
0.53
2
1 This value does not include the weights of the counterweight orthe flange
2 This value does not include the weight of the flange