TECHNICAL DATA

118

OPTIFLEX 2200 C/F

www.krohne.com

07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en

Explosion protection

Explosion protection

Explosion protection

Explosion protection

ATEX (Ex ia or Ex d)

DEKRA 11ATEX0166 X

Compact version

Compact version

Compact version

Compact version

II 1/2 G, 2 G Ex ia IIC T6...T2 Ga/Gb or Ex ia IIC T6...T2 Gb;

II 1/2 D, 2 D Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X;

II 1/2 G, 2 G Ex d ia IIC T6...T2 Ga/Gb or Ex d ia IIC T6...T2 Gb;

II 1/2 D, 2 D Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C Db IP6X

Remote version, transmitter

Remote version, transmitter

Remote version, transmitter

Remote version, transmitter

II 2 G Ex ia [ia Ga] IIC T6...T4 Gb;

II 2 D Ex ia [ia Da] IIIC T90°C Db;

II 2 G Ex d ia [ia Ga] IIC T6...T4 Gb;

II 2 D Ex ia tb [ia Da] IIIC T90°C Db

Remote version, sensor

Remote version, sensor

Remote version, sensor

Remote version, sensor

II 1/2 G Ex ia IIC T6...T2 Ga/Gb

II 1/2 D Ex ia IIIC T90°C Da/Db

II 1/2 G Ex ia IIC T6...T2 Gb

II 1/2 D Ex ia IIIC T90°C Db

ATEX (Ex ic)

DEKRA 13ATEX0051 X

Compact version

Compact version

Compact version

Compact version

II 3 G Ex ic IIC T6...T2 Gc;

II 3 D Ex ic IIIC T90°C Dc

Remote version, transmitter

Remote version, transmitter

Remote version, transmitter

Remote version, transmitter

II 3 G Ex ic [ic] IIC T6...T4 Gc;

II 3 D Ex ic [ic] IIIC T90°C Dc

Remote version, sensor

Remote version, sensor

Remote version, sensor

Remote version, sensor

II 3 G Ex ic IIC T6...T2 Gc;

II 3 D Ex ic IIIC T90°C Dc

IECEx

IECEx DEK 11.0060 X

Compact version

Compact version

Compact version

Compact version

Ex ia IIC T6…T2 Ga/Gb or Ex ia IIC T6…T2 Gb or Ex ic IIC T6…T2 Gc;

Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db or Ex ic IIIC T90°C Dc;

Ex d ia IIC T6...T2 or Ex d ia IIIC T6...T2 Gb;

Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C Db

Remote version, transmitter

Remote version, transmitter

Remote version, transmitter

Remote version, transmitter

Ex ia [ia Ga] IIC T6…T4 Gb or Ex ic IIC T6…T4 Gc;

Ex ia [ia Da] IIIC T90°C Db or Ex ic [ic] IIIC T90°C Dc;

Ex d ia [ia Ga] IIC T6...T4 Gb;

Ex ia tb [ia Da] IIIC T90°C Db

Remote version, sensor

Remote version, sensor

Remote version, sensor

Remote version, sensor

Ex ia IIC T6…T2 Ga/Gb or Ex ia IIC T6…T2 Gb or Ex ic IIC T6…T2 Gc;

Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db or Ex ic IIIC T90°C Dc