Technical data – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 134
8
TECHNICAL DATA
134
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
Double probes: Dimensions in mm
Double probes: Dimensions in inches
Double and coaxial probes
Figure 8-15: Double and coaxial probe options
1 Double rod Ø8 mm / Ø0.31¨ (thread and flange versions)
2 Double cable Ø4 mm / Ø0.16¨ (thread and flange versions)
3 Coaxial Ø22 mm / Ø0.9¨ (thread and flange versions)
4 Coaxial Ø22 mm / Ø0.9¨ (segmented version)
q
q
INFORMATION!
A wide range of counterweights and anchoring solutions are available. For dimensional data,
refer to the pages that follow. For installation data, refer to How to attach probes to the bottom
of the tank on page 23
.
Probes
Dimensions [mm]
L min.
L max.
q
t
Double rod Ø8 mm
1000
1
4000
-
25
Double cable Ø4 mm
2
1000
1
40000
60
Ø38
Coaxial Ø22 mm
600
1
6000
-
-
Coaxial Ø22 mm (segmented)
3
600
1
6000
-
Ø28
1 A shorter probe length is available on request
2 Refer to the end of this section for data about all the probe end options
3 A device with this probe option must be assembled on site. For the assembly procedure, refer to "How to assemble the segmented
coaxial probe" in the Installation chapter.
Probes
Dimensions [inches]
L min.
L max.
q
t
Double rod Ø0.31¨
39
1
158
-
1.0
Double cable Ш0.16¨
2
39
1
1575
2.4
Ш1.5
Coaxial Ø0.9¨
24
1
236
-
-
Coaxial Ø0.9¨ (segmented)
3
24
1
236
-
Ø1.1
1 A shorter probe length is available on request
2 Refer to the end of this section for data about all the probe end options
3 A device with this probe option must be assembled on site. For the assembly procedure, refer to "How to assemble the segmented
coaxial probe" in the Installation chapter.