Appendix, 1 order code – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 149
APPENDIX
10
149
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
10.1 Order code
Make a selection from each column to get the full order code. The characters of the order code
highlighted in light grey describe the standard.
VF20
4 OPTIFLEX 2200 C/F 2-wire loop-powered Guided Radar (TDR) level meter:
OPTIFLEX 2200 C/F 2-wire loop-powered Guided Radar (TDR) level meter:
OPTIFLEX 2200 C/F 2-wire loop-powered Guided Radar (TDR) level meter:
OPTIFLEX 2200 C/F 2-wire loop-powered Guided Radar (TDR) level meter:
Housing material
Housing material
Housing material
Housing material
1 OPTIFLEX 2200 C / Compact (Aluminium housing)
2 OPTIFLEX 2200 C / Compact (Stainless Steel housing)
3 OPTIFLEX 2200 F / Sensor (Aluminium housing) with Remote electronic (Aluminium housing)
1
4 OPTIFLEX 2200 F / Sensor (Stainless Steel housing) with Remote electronic (Stainless Steel housing)
1
5 OPTIFLEX 2200 F / Sensor (Stainless Steel housing) with Remote electronic (Aluminium housing)
1
Approval
Approval
Approval
Approval
2
0 Without
1 ATEX Ex ia IIC T2...T6 + DIP
3
2 ATEX Ex d ia IIC T2...T6 + DIP
3
4 ATEX Ex ic IIC T2...T6 + DIP (Zone 2 and 22)
3
6 IECEx Ex ia IIC T2…T6 + DIP
3
7 IECEx Ex d ia IIC T2…T6 + DIP
3
8 IECEx Ex ic IIC T2...T6 + DIP (Zone 2 and 22)
3
A cFMus IS Cl. I/II/III Div. 1 Gr. A-G; Cl. I Zone 0/20, Ex ia IIC/IIIC T2…T6
1
B cFMus IS-XP/DIP Cl. I/II/III Div. 1, Gr. A-G (A not for Canada); Cl. I Zone 0/20, Ex d/tb IIC/IIIC T2…T6
1
C cFMus NI Cl. I/II/III Div. 2, Gr. A-G; Cl. I Zone 2, Ex nA IIC T2…T6
1
L NEPSI Ex ia IIC T2~T6 + DIP
M NEPSI Ex d ia IIC T2~T6 + DIP
Other approval
Other approval
Other approval
Other approval
0 Without
1 SIL2 (for the compact version (C) with a 4...20 mA output only)
4 CRN (Canadian Registration Number)
5 CRN + SIL2 (for the compact version (C) with a 4...20 mA output only)
Process seal (temperature / pressure / material / notes)
Process seal (temperature / pressure / material / notes)
Process seal (temperature / pressure / material / notes)
Process seal (temperature / pressure / material / notes)
0 Without
1 -40...+150°C (-40...+302°F) / -1...40 barg (-14.5...580 psig) / FKM/FPM (Viton) - for all probes
2 -20...+150°C (-4...+302°F) / -1...40 barg (-14.5...580 psig) / Kalrez® 6375 - for all probes
3 -50...+150°C (-58...+302°F) / -1...40 barg (-14.5...580 psig) / EPDM - for all probes
6 -40...+300°C (-40...+572°F) / -1...40 barg (-14.5...580 psig) / FKM/FPM (Viton)
- only for the HT version of the Ø2 mm single cable probe
7 -20...+300°C (-4...+572°F) / -1...40 barg (-14.5...580 psig) / Kalrez® 6375
- only for the HT version of the Ø2 mm single cable probe
8 -50...+250°C (-58...+482°F) / -1...40 barg (-14.5...580 psig) / EPDM
- only for the HT version of the Ø2 mm single cable probe
VF20
VF20
VF20
VF20
4
Order code (complete this code on the pages that follow)
Order code (complete this code on the pages that follow)
Order code (complete this code on the pages that follow)
Order code (complete this code on the pages that follow)