beautypg.com

Installation, 6 how to install a cable probe in the tank – KROHNE OPTIFLEX 2200 C_F EN User Manual

Page 41

background image

INSTALLATION

3

41

OPTIFLEX 2200 C/F

www.krohne.com

07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en

3.8.6 How to install a cable probe in the tank

• Use two persons to lift the housing and the probe above the process connection.
• Hold the device 1 m / 3½ ft above the tank.
• Unwind the probe carefully into the tank.

Figure 3-35: Wind cable probes and electrical cables carefully

1 Do not wind cable probes less than 400 mm / 16¨ in diameter.
2 Do not wind the electrical cable less than 330 mm / 13¨ in diameter.

WARNING!
If you bend the probe too much, you will damage the device and it will not measure accurately.

Figure 3-36: Installation of devices with cable probes

1 >1 m / 3½ ft