Technical data – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 117
TECHNICAL DATA
8
117
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
Input and output
Measured variable
Time between the emitted and received signal
Current output / HART
Current output / HART
Current output / HART
Current output / HART®
Output signal
4…20 mA HART
®
or 3.8…20.5 mA acc. to NAMUR NE 43
1
Resolution
±
3 µA
Temperature drift (analog)
Typically 50 ppm/K
Temperature drift (digital)
Max. ±15 mm for the full temperature range
Error signal options
High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43; Hold (frozen value - not available if
the output agrees with NAMUR NE 43)
2
PROFIBUS PA
PROFIBUS PA
PROFIBUS PA
PROFIBUS PA
Type
PROFIBUS MDP interface that agrees with IEC 61158-2 with 31.25 kbit/s; voltage
mode (MDP = Manchester Coded Bus Powered)
Function blocks
1 × Physical Block, 1 × Level Transducer Block, 4 × Analog Input Function Blocks
Device power supply
9...32 VDC - bus powered; no additional power supply required
Polarity sensitivity
No
Basic current
15 mA
FOUNDATION
FOUNDATION
FOUNDATION
FOUNDATION™ fieldbus
fieldbus
fieldbus
fieldbus
Type
Physical layer
FOUNDATION™ fieldbus protocol that agrees with IEC 61158-2 and FISCO model
Communication standard
H1
ITK version
6.1
Function blocks
1 × Resource Block (RB), 3 × Transducer Blocks (TB), 3 × Analog Input Blocks (AI), 1
x Proportional Integral Derivative Block (PID)
Analog Input Block: 30 ms
Proportional Integral Derivative Block: 40 ms
Device power supply
Not intrinsically safe: 9...32 VDC
Intrinsically safe: 9...24 VDC
Basic current
14 mA
Maximum error current
20.5 mA (= basic current + error current = 14 mA + 6.5 mA)
Polarity sensitivity
No
Minimum cycle time
250 ms
Output data
Level, distance, ullage conversion, level conversion
Input data
None
Error current FDE
Typically 0 mA (FDE =Fault Disconnection Electronic)
Link Master function
Supported
Display and user interface
User interface options
LCD display (128 × 64 pixels in 8-step greyscale with 4-button keypad)
Languages
9 languages are available: English, German, French, Italian, Spanish, Portuguese,
Japanese, Chinese (simplified) and Russian
Approvals and certification
CE
This device fulfils the statutory requirements of the EC directives. The
manufacturer certifies successful testing of the product by applying the CE mark.
Vibration resistance
EN 60721-3-4 (1...9 Hz: 3 mm / 10...200 Hz:1g; 10g shock ½sinus: 11 ms)