Technical data – KROHNE OPTIFLEX 2200 C_F EN User Manual
Page 127
TECHNICAL DATA
8
127
OPTIFLEX 2200 C/F
www.krohne.com
07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en
Measurement limits (dead zone) in mm and inches
Measurement limits (non-linearity zone) in mm and inches
80 is ε
r
of water; 2.3 is ε
r
of oil
Coaxial probe
Figure 8-10: Measurement limits
1 Device with a coaxial probe
2 Top dead zone:
Top dead zone:
Top dead zone:
Top dead zone: Top part of the probe where measurement is not possible
3 Top non-linearity zone:
Top non-linearity zone:
Top non-linearity zone:
Top non-linearity zone: Top part of the probe with a lower accuracy of ±30 mm / ±1.18¨
4 Bottom non-linearity zone:
Bottom non-linearity zone:
Bottom non-linearity zone:
Bottom non-linearity zone: Bottom part of the probe with a lower accuracy of ±30 mm / ±1.18¨
5 Bottom dead zone:
Bottom dead zone:
Bottom dead zone:
Bottom dead zone: Bottom part of the probe where measurement is not possible
6 Gas (Air)
Gas (Air)
Gas (Air)
Gas (Air)
7 Product
Product
Product
Product
8 L, Probe length
L, Probe length
L, Probe length
L, Probe length
9 Tank Height
Tank Height
Tank Height
Tank Height
10 Minimum distance from the probe to a metallic tank wall:
Minimum distance from the probe to a metallic tank wall:
Minimum distance from the probe to a metallic tank wall:
Minimum distance from the probe to a metallic tank wall: Coaxial probe = 0 mm / 0¨
Dead zone
ε
r
= 80
ε
r
= 2.3
Top 2
Bottom 5
Top 2
Bottom 5
[mm]
[inches]
[mm]
[inches]
[mm]
[inches]
[mm]
[inches]
Coaxial
150
5.91
0
0
200
7.87
20
0.79
Non-linearity
zone
ε
r
= 80
ε
r
= 2.3
Top 3
Bottom 4
Top 3
Bottom 4
[mm]
[inches]
[mm]
[inches]
[mm]
[inches]
[mm]
[inches]
Coaxial
0
0
50
1.97
0
0
150
5.91