3.5 How to prepare the tank before you install the device

3.5.1 Pressure and temperature ranges

Permitted temperature ranges for gaskets

CAUTION!
To avoid measuring errors and device malfunction, obey these precautions.

Figure 3-4: Pressure and temperature ranges

1 Temperature at the process connection

The temperature at the process connection must stay in the temperature range of the gasket material unless the de-
vice is a High-Temperature version. Refer to the table "Permitted temperature ranges for gaskets" that follows and
to "Technical data" on page 116.
Devices with Hazardous Location approvals: see supplementary instructions

2 Ambient temperature for operation of the display

-20...+60°C / -4...+140°F
If the ambient temperature is not between these limits, the display screen switches off automatically

3 Ambient temperature

Non-Ex devices: -40...80°C / -40...176°F
Devices with Hazardous Location approvals: see supplementary instructions

4 Process pressure

-1...40 barg / -14.5...580 psig

WARNING!
The process connection temperature range must agree with the temperature limits of the
gasket material.

Gasket material

Permitted temperature ranges for gaskets

Standard version

High-Temperature version

[°C]

[°F]

[°C]

[°F]

FKM/FPM

-40…+150

-40…+302

-40…+300

-40…+572

Kalrez

®

6375

-20…+150

-4…+302

-20…+300

-4…+572

EPDM

-50…+150

-58…+302

-50…+250

-58…+482