INSTALLATION

3

25

OPTIFLEX 2200 C/F

www.krohne.com

07/2013 - 4000668002 - HB OPTIFLEX 2200 R02 en

The probe counterweight has a hole with an M8 internal thread. You can attach the probe
counterweight to a threaded end.

• Weld a tube with an internal diameter of 23...25 mm / 0.91...1¨ to the bottom of the tank.

i

Make sure the tube aligns with the process connection at the top of the tank.

• Lower the probe into the tank.
• Put the end of the probe into the tube.

If this is not possible, you can attach braces to the probe.

Single cable Ø2 mm / 0.08¨

Figure 3-16: How to attach a Ø2 mm / 0.08¨ single cable probe to keep it straight

Coaxial Ø22 mm / 0.8¨

Figure 3-17: How to attach a coaxial probe to keep it straight