SAFETY INSTRUCTIONS

1

7

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

1.1 Software history

Data about software revisions is shown in the Supervisor menu. Go to Test > Information >

Test > Information >

Test > Information >

Test > Information >

Device ID

Device ID

Device ID

Device ID. For more data, refer to

Function description

on page 73. If it is not possible to refer to

the device menu, record the serial number of the device (given on the device nameplate) and
speak to the supplier.

1.2 Intended use

This TDR level transmitter measures distance, level, mass and volume of liquids, pastes,
slurries, granulates and powders. It can also measure level and interface of liquids at the same
time.

It can be installed on tanks, silos and open pits.

Release date

(back end)

[YYYY-MM-DD]

Back end

Front end

DTM revision

Hardware

NE 53 level

2005-10-18

1.0.2.73

1.0.0.22

1.0.0.24

2139590100

n/a

2006-02-27

1.02.75

1.0.0.22

1.0.0.24

2139590100

3

2006-05-29

1.02.75

1.0.0.25

1.0.0.24

2139590100

3

2006-09-01

1.02.77

1.0.0.26

1.0.0.32

2139590100

3

2007-11-21

1.02.79

1.0.0.27

1.0.0.33

2139590100

3

2008-06-22

1.02.80

1.0.0.27

1.0.0.34

2139590100

3

2010-03-01

2.02.82

1.02.82

1

1.0.0.28

1.0.0.35

4000659401

2

1

3

2010-05-01

2.02.83

1.02.83

1

1.0.0.28

1.0.0.37

3

4000659401

4

3

n/a

2012-03-05

2.02.84

1.02.84

1

1.0.0.28

1.0.0.37

3

4000659401

5

3

3

1 This back end firmware revision is only used for device upgrades
2 It is possible to upgrade the hardware (revision 2139590100) with back end firmware revision 1.02.82
3 If your computer uses the Windows XP operating system, install DTM revision V 1.0.0.35. If your computer uses the Windows 7 operating

system, install DTM revision V 1.0.0.37.

4 It is possible to upgrade the hardware (revision 2139590100) with back end firmware revision 1.02.83
5 It is possible to upgrade the hardware (revision 2139590100) with back end firmware revision 1.02.84

CAUTION!
Responsibility for the use of the measuring devices with regard to suitability, intended use and
corrosion resistance of the used materials against the measured fluid lies solely with the
operator.

INFORMATION!
The manufacturer is not liable for any damage resulting from improper use or use for other than
the intended purpose.