8.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Measuring principle
2-wire loop-powered level transmitter; Time Domain Reflectometry (TDR)
Application range
Level measurement of liquids, pastes, slurries, powders and granulates
Primary measured value
Time between the emitted and received signal
Secondary measured value
Distance, level, volume, mass and/or interface
Design
Construction
The measurement system consists of a measuring sensor (probe) and a signal
converter which is available in a compact or remote version
Options
Integrated LCD display with sun cover (-20…+60°C / -4…+140°F);
if the ambient temperature is not in these limits, the display switches off
2nd current output
ESD protection (max. 30 kV)
Metaglas
®
(dual process sealing system for dangerous products (ammonia,
chlorine, ...))
1
Remote housing connected to the probe via a flexible conduit
Standard lengths: 2 m / 6.6 ft, 4.5 m / 14.8 ft, 9.5 m / 31.2 ft and 14.5 m / 47.6 ft
Probe end types (not for rod and coaxial probes)
Probe end types (not for rod and coaxial probes)
Probe end types (not for rod and coaxial probes)
Probe end types (not for rod and coaxial probes)
Standard: Counterweights (refer to counterweight dimensions in "Technical data:
Dimensions and weights")
Options: Turnbuckle, chuck, threaded end, crimped end, open end
Accessories
Weather protection
Max. measuring range
Double rod Ø8 mm / 0.32¨: 4 m / 13 ft
Single rod Ø8 mm / 0.32¨: 4 m / 13 ft
Single rod Ø8 mm / 0.32¨ (segmented): 6 m / 20 ft
Coaxial Ø22 mm / 0.87¨: 6 m / 20 ft
Coaxial Ø22 mm / 0.87¨ (segmented): 6 m / 20 ft
Double cable Ø4 mm / 0.16¨: 8 m / 26 ft
Single cable Ø2 mm / 0.08¨: 35 m / 115 ft (for liquids only)
Single cable Ø4 mm / 0.16¨: 35 m / 115 ft (For liquids only. An angled probe is
available on request for installations with very low ceilings or objects in the tank
that prevent installation on top of the tank.)
Single cable Ø8 mm / 0.32¨: 35 m / 115 ft (for solids only)
Tolerance, probe length
±0.5%
Dead zone
This depends on the type of probe. For more data, refer to
Measurement limits
on
page 141.
Display and User interface
Display and User interface
Display and User interface
Display and User interface
Display
LCD display
9 lines, 160×160 pixels in 8-step grayscale with 4-button keypad
Interface languages
English, German, French, Italian, Spanish, Portuguese, Japanese, Simplified
Chinese and Russian