ELECTRICAL CONNECTIONS

4

59

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

4.5 Networks

4.5.1 General information

The device uses the HART

®

communication protocol. This protocol agrees with the HART

®

Communication Foundation standard. The device can be connected point-to-point. It can also
operate in a multi-drop network of up to 15 devices.

The device output is factory-set to communicate point-to-point. To change the communication
mode from point-to-point

point-to-point

point-to-point

point-to-point to multi-drop

multi-drop

multi-drop

multi-drop, refer to

Network configuration

on page 86.

4.5.2 Point-to-point networks

Figure 4-4: Point-to-point connection (non-Ex)

1 Address of the device (0 for a point-to-point connection)
2 4...20 mA + HART

®

3 Resistor for HART

®

communication

4 Power supply
5 HART

®

modem

6 HART

®

communication device