TECHNICAL DATA
8
133
OPTIFLEX 1300 C
www.krohne.com
03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en
Flange versions for double rod and double cable probes
Flange versions for double rod and double cable probes
Flange versions for double rod and double cable probes
Flange versions for double rod and double cable probes
EN 1092-1
DN50...80 in PN40 (Form B1), DN100…200 in PN16 or PN40 (Form B1), DN50...150
in PN63 or PN100 (Form B1); others on request
Optional flange facing: Forms C, D, E and F
ASME B16.5
2¨…8¨ in 150 lb, 2¨...6¨ in 300 lb RF, 2¨...4¨ in 600 lb RF; 3¨...4¨ 900 lb RF, 2¨ in 900 lb
or 1500 lb RJ; others on request
Optional flange facing: RJ (Ring Joint)
JIS B2220
50…100A in 10K; others on request
Flange versions for single cable Ø8 mm / 0.32
Flange versions for single cable Ø8 mm / 0.32
Flange versions for single cable Ø8 mm / 0.32
Flange versions for single cable Ø8 mm / 0.32¨ cable probes
cable probes
cable probes
cable probes
EN 1092-1
DN40...80 in PN40 (Form B1), DN100…200 in PN16 or PN40 (Form B1), DN40…150
in PN63 or PN100 (Form B1); others on request
Optional flange facing: Forms C, D, E and F
ASME B16.5
1½¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb RF, 1½¨...4¨ in 600 lb RF; 3¨...4¨ 900 lb RF,
1½¨...2¨ in 900 lb or 1500 lb RJ; others on request
Optional flange facing: RJ (Ring Joint)
JIS B2220
40…100A in 10K; others on request
Flange versions for single cable Ø2 mm / 0.08
Flange versions for single cable Ø2 mm / 0.08
Flange versions for single cable Ø2 mm / 0.08
Flange versions for single cable Ø2 mm / 0.08¨ probe
probe
probe
probe
EN 1092-1
DN25...80 in PN40 (Form B1), DN100…200 in PN16 or PN40 (Form B1), DN40…150
in PN63 or PN100 (Form B1); others on request
Optional flange facing: Forms C, D, E and F
ASME B16.5
1¨…8¨ in 150 lb RF, 1½¨...6¨ in 300 lb RF, 1¨...4¨ in 600 lb RF, 3¨...4¨ in 900 lb RF,
1¨...2¨ in 900 lb or 1500 lb RJ, 1¨ in 2500 lb RJ; others on request
Optional flange facing: RJ (Ring Joint)
JIS B2220
40…100A in 10K; others on request
Flange versions for other probes
Flange versions for other probes
Flange versions for other probes
Flange versions for other probes
EN 1092-1
DN25...80 in PN40 (Form B1), DN100…200 in PN16 or PN40 (Form B1), DN25…150
in PN63 or PN100 (Form B1); others on request
Optional flange facing: Forms C, D, E and F
ASME B16.5
1¨…8¨ in 150 lb RF, 1½¨...6¨ in 300 lb RF, 1¨...4¨ in 600 lb RF, 3¨...4¨ in 900 lb RF,
1¨...2¨ in 900 lb or 1500 lb RJ; others on request
Optional flange facing: RJ (Ring Joint)
JIS B2220
40…100A in 10K; others on request
Other options for single and double rod probes
Other options for single and double rod probes
Other options for single and double rod probes
Other options for single and double rod probes
SMS
Available on request
Tri-clamp
Available on request
Others
Others on request
Electrical connections
Power supply
Terminals output 1
Terminals output 1
Terminals output 1
Terminals output 1 – Non-Ex / Ex i:
Non-Ex / Ex i:
Non-Ex / Ex i:
Non-Ex / Ex i:
14…30 VDC; min./max. value for an output of 22 mA at the terminal
Terminals output 1
Terminals output 1
Terminals output 1
Terminals output 1 – Ex d:
Ex d:
Ex d:
Ex d:
20…36 VDC; min./max. value for an output of 22 mA at the terminal
Terminals output 2
Terminals output 2
Terminals output 2
Terminals output 2 – Non-Ex / Ex i / Ex d:
Non-Ex / Ex i / Ex d:
Non-Ex / Ex i / Ex d:
Non-Ex / Ex i / Ex d:
10…30 VDC; min/max. value for an output of 22 mA at the terminal (additional
power supply needed – output only)
Cable entry
M20×1.5; ½ NPT
G ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)
M25×1.5 (for stainless steel housings only)
Cable gland
Standard: none
Options: M20×1.5 (for non-Ex and Ex-approved devices with M20×1.5 and M25×1.5
cable entries); others are available on request
Cable entry capacity (terminal)
0.5…1.5 mm²