Service – KROHNE OPTIFLEX 1300C EN User Manual
Page 115
SERVICE
7
115
OPTIFLEX 1300 C
www.krohne.com
03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en
7 Push 4 × [^
^
^
^] to go back to the Operating Mode.
8 Push the [^
^
^
^] button to enter the Configuration Mode (Service).
i
If the device has password protection, The display screen shows the text "CodE2".
9 Give the password for the SERVICE menu. If you do not have the password, speak to the sup-
plier.
10 Record parameters in these menu items: 2.5 M.CAL. SPEED. and 2.7 OFFSET.
11 Push 2 × [^
^
^
^] to go back to the Operating Mode.
12 De-energize the device.
13 Remove the electrical cables.
14 Attach the signal converter cover.
1 Remove the 4 socket head screws at the bottom of the signal converter with a 5 mm Allen
wrench.
2 Remove the signal converter from the process connection. Make sure that you do not damage
the 50 ohm wire.
3 Disconnect the 50 ohm wire connector from the process connection.
Procedure 2A: How to remove the BM 100 signal converter (non-Ex devices)
Figure 7-4: Procedure 2A: How to remove the BM 100 signal converter (non-Ex devices)
WARNING!
De-energize the device and disconnect the electrical cables before you remove the signal
converter.